3.
3.1.
INSTRUCTIONS FOR USE
Humidity regulation with an inbuilt digital humidistat located in the cover of the equipment
3
WALL-MOUNTED SWIMMING POOL DEHUMIDIFIER - OWNER´S & INSTALLATION MANUAL
The inbuilt humidistat is located in the cover of the device. It reads the humidiy of the incoming air, and depending on the set value,
switches on the compressor. In indoor swimming pool halls, the optimal air humidity level should range between 55% and 65 %.
Decreasing the level of humidity under the above mentioned range is not desirable, considerating the physiological aspects as well
as the aspects of providing building protection. Moreover, it increases the consumption of electrical energy. The humidistat can be
controlled by the user.
Humidistat display (front view)
Luminous point
signals, that the
humidity is shown on
display.
Luminous point indicates that
the regulator gives signal to
dehumidify, i.e. requested
humidity is lower than actual.
Luminous point indicates
that the regulator gives
signal to heat the air. This is
applicable if LPHW and
Solenoid valve are installed.
Not illuminated point
indicates that the requested
air temperature is lower than
actual.
Luminous point signals,
that the temperature is
shown on display.
Failure reporting
Memory failure. Switch off and then switch on again the electrical connection.
If the failure reporting continues, please ask us to change the component.
Sensor failure. The electrical connection of the sensor is broken off.
Please control the cable.
Sensor failure. The sensor is short-circuited. Please control the cable.
Er1
0-E
S-E