The design of the device enables its safe mounting and proper fixation even if lifted accidentally. There are slots for safety screws
accessible after dismounting a front fibreglass cover, located in the top corners of the rear plate. There is an arrow that indicates
safety screw slots in the rear plate. The safety screw is fixed through a slot in the rear plate into a wall fastener. It prevents the
device from being pulled out and from falling out from a mounting bracket. At the same time, it secures a vertical position of the
device together with a device alignment with a wall.
6.4. Position assuring of the device
7
Condensed water is drained from the device by the force of gravity. It is necessary to locate the device in a way that enables
sufficient condensed water gradient. The condensate must be delivered through a siphon into the sewer or into the outside
environmemt. It is strictly forbidden to deliver the condensate back into the swimming pool, as it may be bacterially contaminated.
There is a tube for condensed water delivery located at the bottom of the device, on the left side. This tube must be pluged into
a sewerage pipe with an internal diameter of minimum 18 mm.
6.5. Condensate drain
DRY 300 METAL/ and DRY 500 METAL/ with connections (front view)SILVER, DRY400 METAL/SILVER SILVER
Connecting the device onto the mains and protection securing must satisfy the requirements of relevant norms. Connection
requirements are the following: 220-240 V/50Hz, protection 10A (DRY 300 METAL/SILVER and DRY 400 METAL/SILVER) and 16A
(DRY 500 METAL/SILVER) with a mains-fuse that has a current-carrying differential disconnecting capacity, not exceeding 30mA.
There is a terminal for connection to the mains, located on the left hand side of the device. The master switch of the device must be
located outside the swimming pool area, it must be bipolar and with L and N conductors´ disconnecting. The device for
disconnecting the appliance from the mains must be inbuilt to a steady point. There has to be a distance of min. 3 mm between the
contacts (when switched off) for all the poles. Connection of the device to the mains must be performed by a certified electrician.
6.6 Connecting the device to the mains
Preparation of electric power supply, condensate drain and console mounting
REAR PLATE
SAFETY SCREW SLOTS
WALL-MOUNTED SWIMMING POOL DEHUMIDIFIER - OWNER´S & INSTALLATION MANUAL
50
100
44
117
50
15
THREAD G ½ '’ MALE
LOCATION OF CONNECTION- FROM BACK SIDE
POWER SUPPLY
2
CYSY WIRE 3C x 1.5 (3C x 2.5) mm
(FROM THE REAR)
CONDENSATE DRAINAGE (FROM THE REAR)
PIPING WITH MINIMUM INTERNAL DIAMETER OF 18 mm